0-22 Watts, Open Frame, Universal Input, ITE, Dual Output, Switchmode Power Supply
INPUT VOLTAGE:
90 VAC TO 264 VAC
INPUT CURRENT:
≤ 0.5 A RMS AT 90 VAC INPUT
INPUT FREQUENCY:
47 Hz - 63 Hz
OUTPUT CURRENT:
± 3.3 VDC @ 6.0 A; +5 VDC @ 0.5 A
OUTPUT POWER (RATED):
22.3 WATTS MAX
OUTPUT RIPPLE (PEAK TO PEAK):
1% OF OUTPUT VOLTAGE TYPICAL
OUTPUT REGULATION (LINE/LOAD):
+ 5 % FOR MAIN OUTPUT, MEASURED AT O/P CONNECTOR
LINE REGULATION:
± 0.5% MAX AT FULL LOAD
TURN ON/ TURN OFF OVERSHOOT:
4% MAX 500 µs MAX RECOVERY TIME FOR 25% STEP LOAD
TURN-ON DELAY:
1 SEC MAX
HOLD-UP TIME:
16 mSEC MIN AT NOMINAL INPUT AND FULL LOAD
INRUSH CURRENT:
20 A MAX AT COLD START FOR N.A. (40 A FOR EURO)
EFFICIENCY:
75% TYPICAL
SWITCHING FREQUENCY:
100 kHz TYPICAL
OVER-VOLTAGE PROTECTION:
VOLTAGE LIMITED LESS 130% OF NOMINAL VOLTAGE
OVER-CURRENT/SHORT CIRCUIT:
CONSTANT CURRENT AT 110% TO 130% OF NOMINAL LOAD
SHORT CIRCUIT:
MOMENTARY OUTPUT SHORT CIRCUIT PROTECTED
OTHER PROTECTION:
INPUT FUSING
SAFETY APPROVALS:
UR TO UL 60950, C-UR TO 22.2 # 950 CLASS II W/FUNCTIONAL GROUND, CE CLASS I
DIELECTRIC WITHSTAND VOLTAGE:
5656 VAC PRIMARY-SECONDARY; 2121 VAC, PRIMARY- GROUND
LEAKAGE CURRENT:
< 3.5 mA
LINE SURGE:
EN 61000-4-5 LEVEL 4
EMI:
COMPLIES WITH EN55022 , CLASS B AND FCC PART 15 CLASS B WHEN TESTED WITH A RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED
CE MARK:
TESTED TO COMPLY WITH EN61000-3-2 EN61000-3-3, AND EN50082-1, INCLUDING EN61000-4-2 (SYSTEM LEVEL), EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, LEVEL 4. UNIT IS ELIGIBLE FOR CE MARK.
MTBF:
GREATER THAN 200,000 HOURS AT 25°C AMBIENT TEMP.
OPERATING TEMPERATURE:
0°C TO 40°C
STORAGE TEMPERATURE:
-40°C TO 80°C
HUMIDITY:
0% TO 90% RELATIVE HUMIDITY

SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS.
INPUT CONNECTOR:
IEC 60320/C14, 3 PIN MALE, PANEL MOUNT RECEPTACLE.
CONFIGURATION: OPEN FRAME SWITCHING POWER SUPPLY, WITH MOUNTING HOLES, POSITIONED AS SHOWN.
OUTPUT HARNESS: CONDUCTOR, 24 AWG STRANDED WIRE, FLAT UL 1007 CORD TYPE, COLOR BLACK, LENGTH OF CORD: 1830 + 50 mm. CORD IS MEASURED FROM THE PCB TO THE END OF THE CONNECTOR. CABLE IS TO BE MARKED WITH WIRE GAUGE, AND ALL APPLICABLE RATING AND SAFETY APPROVALS.
OUTPUT CONNECTOR:
FEMALE 3.96 mm PITCH, MOLEX 3961, 6 CIRCUIT, OR EQUIVALENT.
INPUT CONNECTOR:
IEC 60320/C14, 3 PIN MALE, PANEL MOUNT RECEPTACLE
0-65 Watts, 3′′ x 5′′ Open Frame, Universal Input, Single Output Family, ITE
INPUT VOLTAGE:
UNIVERSAL INPUT FROM 100 VAC TO 240 VAC
INPUT CURRENT:
1.5 A @ 65 W MAXIMUM AT 100 VAC FULL LOAD
INPUT FREQUENCY:
47 Hz - 63 Hz
OUTPUT CURRENT:
NO MINIMUM LOAD REQUIRED
OUTPUT POWER (RATED):
65 WATTS MAX FREE AIR CONVECTION
OUTPUT RIPPLE (PEAK TO PEAK):
LESS THAN 1% OF OUTPUT VOLTAGE
OUTPUT LOAD REGULATION:
±2% MEASURED AT THE OUTPUT CONNECTOR END OF THE PSU
LINE REGULATION:
±0.5% OF NOMINAL VOLTAGE MEASURED AT O/P CONNECTOR
TURN ON/TURN OFF OVERSHOOT:
5% MAXIMUM, 1 ms TYPICAL RECOVERY TIME FOR 25% TO 50% STEP LOAD
TURN-ON DELAY:
3 SEC TYPICAL
HOLD-UP TIME:
12 ms MINIMUM AT 65 W AT 120 VAC INPUT
INRUSH CURRENT:
20 A MAXIMUM AT 120 VAC AND 40 A MAXIMUM AT 230 VAC
EFFICIENCY:
80% TYPICAL AT NOMINAL INPUT AND FULL LOAD
SWITCHING FREQUENCY:
100 kHz TYPICAL
OVER-VOLTAGE PROTECTION:
OUTPUT VOLTAGE LIMITED BY CROWBAR METHOD, HICCUP MODE
OVER-CURRENT/SHORT CIRCUIT:
HICCUP MODE, UNIT WILL RECOVER ONCE FAULT IS REMOVED
OTHER PROTECTION:
INPUT LINE FUSING
SAFETY APPROVALS:
EN60950, UL/CSA60950 3ED., EN60601, UL60601 A1/A2, CB, DEMKO, CE TO EN61000-3-2, EN610003-3, EN61000-4-2, EN61000-4-3, EN61000-4-4 EN61000-4-5, EN61000-4-6, EN61000-4-11, EMI TO EN55011 MEDICAL AND EN55022 ITE CLASS B, TESTED WITH RESISTIVE LOAD
DIELECTRIC WITHSTAND VOLTAGE:
4242 VDC (3000 VAC) FROM PRIMARY TO SECONDARY 2121 VDC (1500 VAC) SECONDARY TO GROUND
LEAKAGE CURRENT:
LESS THAN 300 µA AT 240 VAC
LINE SURGE:
EN 61000-4-5 LEVEL 2
EMI:
COMPLIES WITH EN55022 CLASS B AND FCC PART 15 CLASS B WHEN TESTED WITH RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED EMI.
CE MARK:
TESTED TO COMPLY WITH EN61000-3-2 EN610003-3 AND EN50082-1 INCLUDING EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11.
MTBF (BELCORE METHOD I, CASE 1):
1.1 MILLION HRS, 40C, GROUND BENIGN
OPERATING TEMPERATURE:
-20°C TO 50°C AMBIENT TEMPERATURE
STORAGE TEMPERATURE:
-40°C TO 80°C
HUMIDITY:
OPERATING, NON-CONDENSING; 5% TO 90% RH

SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS.
OPEN FRAME SWITCHING POWER SUPPLY WITH MOUNTING HOLES POSITIONED AS BELOW
INPUT CONNECTOR (CON1):
MOLEX 3-PIN WITH CENTER PIN REMOVED MOLEX PN: 26-60-4030 MATES W/PN: 09-50-3031, PIN 1: AC NEUTRAL, PIN 3: AC LINE, EC1: EARTH GROUND FOR CLASS I UNITS ONLY
INPUT CONNECTOR (CON1 OPTION)
WIRE HARNESS WITH MOLEX HEADER PN: 09-50-3031 WITH AWG 18 STRANDED WIRE, UL1007/UL1015 WITH CONFIGURABLE LENGTH UP TO 100 mm. BLACK OR BROWN FOR AC LINE; WHITE OR BLUE FOR AC NEUTRAL; GREEN WITH YELLOW STRIPE FOR EARTH GROUND
0-65 Watts, 3′′ x 5′′ Open Frame, Universal Input, Dual and Triple Output Family, ITE
INPUT VOLTAGE:
UNIVERSAL INPUT FROM 100 VAC TO 240 VAC
INPUT CURRENT:
1.5 A @ 65 W MAXIMUM AT 100 VAC FULL LOAD
INPUT FREQUENCY:
47 Hz - 63 Hz
OUTPUT CURRENT:
NO MINIMUM LOAD REQUIRED
OUTPUT POWER (RATED):
65 WATTS MAX FREE AIR CONVECTION
OUTPUT RIPPLE (PEAK TO PEAK):
LESS THAN 1% OF OUTPUT VOLTAGE
OUTPUT LOAD REGULATION:
±2% MEASURED AT THE OUTPUT CONNECTOR END OF THE PSU
LINE REGULATION:
±0.5% OF NOMINAL VOLTAGE MEASURED AT O/P CONNECTOR
TURN ON/TURN OFF OVERSHOOT:
5% MAXIMUM, 1 ms TYPICAL RECOVERY TIME FOR 25% TO 50% STEP LOAD
TURN-ON DELAY:
3 SEC TYPICAL
HOLD-UP TIME:
12 ms MINIMUM AT 65 W AT 120 VAC INPUT
INRUSH CURRENT:
20 A MAXIMUM AT 120 VAC AND 40 A MAXIMUM AT 230 VAC
EFFICIENCY:
80% TYPICAL AT NOMINAL INPUT AND FULL LOAD
SWITCHING FREQUENCY:
100 kHz TYPICAL
OVER-VOLTAGE PROTECTION:
OUTPUT VOLTAGE LIMITED BY CROWBAR METHOD, HICCUP MODE
OVER-CURRENT/SHORT CIRCUIT:
HICCUP MODE, UNIT WILL RECOVER ONCE FAULT IS REMOVED
OTHER PROTECTION:
INPUT LINE FUSING
SAFETY APPROVALS:
EN60950, UL/CSA60950 3ED., EN60601, UL60601 A1/A2, CB, DEMKO, CE TO EN61000-3-2, EN610003-3, EN61000-4-2, EN61000-4-3, EN61000-4-4 EN61000-4-5, EN61000-4-6, EN61000-4-11, EMI TO EN55011 MEDICAL AND EN55022 ITE CLASS B, TESTED WITH RESISTIVE LOAD
DIELECTRIC WITHSTAND VOLTAGE:
4242 VDC (3000 VAC) FROM PRIMARY TO SECONDARY 2121 VDC (1500 VAC) SECONDARY TO GROUND
LEAKAGE CURRENT:
LESS THAN 300 µA AT 240 VAC
LINE SURGE:
EN 61000-4-5 LEVEL 2
EMI:
COMPLIES WITH EN55022 CLASS B AND FCC PART 15 CLASS B WHEN TESTED WITH RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED EMI.
CE MARK:
TESTED TO COMPLY WITH EN61000-3-2 EN610003-3 AND EN50082-1 INCLUDING EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11.
MTBF (BELCORE METHOD I, CASE 1):
1.1 MILLION HRS, 40C, GROUND BENIGN
OPERATING TEMPERATURE:
-20°C TO 50°C AMBIENT TEMPERATURE
STORAGE TEMPERATURE:
-40°C TO 80°C
HUMIDITY:
OPERATING, NON-CONDENSING; 5% TO 90% RH

SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS.
INPUT CONNECTOR (CON1):
MOLEX 3-PIN WITH CENTER PIN REMOVED MOLEX PN: 26-60-4030 MATES WITH PN: 09-50-3031, PIN 1: AC NEUTRAL, PIN 3: AC LINE, EC1: EARTH GROUND FOR CLASS I UNITS ONLY
INPUT CONNECTOR (CON1 OPTION)
WIRE HARNESS WITH MOLEX HEADER PN: 09-50-3031 WITH AWG 18 STRANDED WIRE, UL1007/UL1015 WITH CONFIGURABLE LENGTH UP TO 100mm. BLACK OR BROWN FOR AC LINE; WHITE OR BLUE FOR AC NEUTRAL; GREEN WITH YELLOW STRIPE FOR EARTH GROUND
72 Watts, Switchmode Power Supply, Single Output, Family Desktop, Universal Input, ITE Class I
INPUT VOLTAGE:
90 VAC TO 264 VAC
INPUT CURRENT:
≤ 1.6 A RMS AT 90 VAC INPUT
INPUT FREQUENCY:
47 Hz - 63 Hz
OUTPUT CURRENT:
NO LOAD TO FULL LOAD, NO MINIMUM LOAD REQUIRED
OUTPUT POWER (RATED):
72 WATTS MAX
OUTPUT RIPPLE (PEAK TO PEAK):
≤ 1% OR 100 mV
OUTPUT REGULATION (LINE/LOAD):
±5% FOR MAIN OUTPUT, MEASURED AT O/P CONNECTOR
LINE REGULATION:
+0.5% MAX AT FULL LOAD
TURN ON/TURN OFF OVERSHOOT:
4% MAX; 500 µs MAX RECOVERY TIME FOR 25% STEP LOAD
TURN-ON DELAY:
1 SEC MAX
HOLD-UP TIME:
16 mSEC MIN AT NOMINAL INPUT AND FULL LOAD
INRUSH CURRENT:
20 A MAX AT COLD START FOR N.A. (40 A FOR EURO)
EFFICIENCY:
75% TYPICAL
SWITCHING FREQUENCY:
100 kHz TYPICAL
OVER-VOLTAGE PROTECTION:
VOLTAGE LIMITED LESS 130% OF NOMINAL VOLTAGE
OVER-CURRENT/SHORT CIRCUIT:
HICCUP WITH AUTO RECOVERY TO 1.1 - 1.3 IO
OTHER PROTECTION:
INPUT FUSING
SAFETY APPROVALS:
UL60950 (3rd ED.), CUL TO 22.2# 60950 (3rd ED.), TUV TO EN60950-1:2001, PSE TO J60950 CE CLASS I
DIELECTRIC WITHSTAND VOLTAGE:
1500 VAC PRIMARY-SECONDARY; 1500 VAC PRIMARY-GROUND
LEAKAGE CURRENT:
≤ 3.5 mA
LINE SURGE:
EN 61000-4-5 LEVEL 4
EMI:
COMPLIES WITH EN55022, CLASS B AND FCC PART 15 CLASS B WHEN TESTED WITH A RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED
CE MARK:
TESTED TO COMPLY WITH EN61000-3-2 EN61000-3-3, AND EN50082-1, INCLUDING EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, LEVEL 4. UNIT IS ELIGIBLE FOR CE MARK.
MTBF:
GREATER THAN 200,000 HOURS AT 25°C AMBIENT TEMPERATURE
OPERATING TEMPERATURE:
0°C TO 40°C
STORAGE TEMPERATURE:
-40°C TO 80°C
HUMIDITY:
0% TO 90% RELATIVE HUMIDITY

SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS.
HOUSING: HIGH IMPACT PLASTIC, 94V0 POLYCARBONATE, NON-VENTED, COLOR BLACK
INPUT CONNECTOR CONFIGURATION:
CLASS 1 MODEL IEC60320/C14, AC POWER RECEPTACLE WITH 3 MALE PINS. GROUND PIN CONNECTED INTERNALLY TO DC COMMON
Back to top
Home | Browse Categories | Featured Companies Sitemap | Featured Categories Sitemap
Guides | Forums | FAQs | Contact ThomasNet | Provide Feedback

Log In to MyThomas | Sign Up for MyThomas | Log In to Client Center

Advertising Services | Free Listing | Press Room | Careers

© 2010 Thomas Publishing Company. All rights reserved. See Terms and Conditions or Privacy Statement. Last Modified January 6, 2010.
Sign Up | Log In | Product News | Promote Your Business