Power Supplies: Computer related categories
 | 0-22 Watts, Open Frame, Universal Input, ITE, Dual Output, Switchmode Power Supply INPUT VOLTAGE: 90 VAC TO 264 VAC INPUT CURRENT: ≤ 0.5 A RMS AT 90 VAC INPUT INPUT FREQUENCY: 47 Hz - 63 Hz OUTPUT CURRENT: ± 3.3 VDC @ 6.0 A; +5 VDC @ 0.5 A OUTPUT POWER (RATED): 22.3 WATTS MAX OUTPUT RIPPLE (PEAK TO PEAK): 1% OF OUTPUT VOLTAGE TYPICAL OUTPUT REGULATION (LINE/LOAD): + 5 % FOR MAIN OUTPUT, MEASURED AT O/P CONNECTOR LINE REGULATION: ± 0.5% MAX AT FULL LOAD TURN ON/ TURN OFF OVERSHOOT: 4% MAX 500 µs MAX RECOVERY TIME FOR 25% STEP LOAD TURN-ON DELAY: 1 SEC MAX HOLD-UP TIME: 16 mSEC MIN AT NOMINAL INPUT AND FULL LOAD INRUSH CURRENT: 20 A MAX AT COLD START FOR N.A. (40 A FOR EURO) EFFICIENCY: 75% TYPICAL SWITCHING FREQUENCY: 100 kHz TYPICAL OVER-VOLTAGE PROTECTION: VOLTAGE LIMITED LESS 130% OF NOMINAL VOLTAGE OVER-CURRENT/SHORT CIRCUIT: CONSTANT CURRENT AT 110% TO 130% OF NOMINAL LOAD SHORT CIRCUIT: MOMENTARY OUTPUT SHORT CIRCUIT PROTECTED OTHER PROTECTION: INPUT FUSING SAFETY APPROVALS: UR TO UL 60950, C-UR TO 22.2 # 950 CLASS II W/FUNCTIONAL GROUND, CE CLASS I DIELECTRIC WITHSTAND VOLTAGE: 5656 VAC PRIMARY-SECONDARY; 2121 VAC, PRIMARY- GROUND LEAKAGE CURRENT: < 3.5 mA LINE SURGE: EN 61000-4-5 LEVEL 4 EMI: COMPLIES WITH EN55022 , CLASS B AND FCC PART 15 CLASS B WHEN TESTED WITH A RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED CE MARK: TESTED TO COMPLY WITH EN61000-3-2 EN61000-3-3, AND EN50082-1, INCLUDING EN61000-4-2 (SYSTEM LEVEL), EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, LEVEL 4. UNIT IS ELIGIBLE FOR CE MARK. MTBF: GREATER THAN 200,000 HOURS AT 25°C AMBIENT TEMP. OPERATING TEMPERATURE: 0°C TO 40°C STORAGE TEMPERATURE: -40°C TO 80°C HUMIDITY: 0% TO 90% RELATIVE HUMIDITY
SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS. INPUT CONNECTOR: IEC 60320/C14, 3 PIN MALE, PANEL MOUNT RECEPTACLE. CONFIGURATION: OPEN FRAME SWITCHING POWER SUPPLY, WITH MOUNTING HOLES, POSITIONED AS SHOWN. OUTPUT HARNESS: CONDUCTOR, 24 AWG STRANDED WIRE, FLAT UL 1007 CORD TYPE, COLOR BLACK, LENGTH OF CORD: 1830 + 50 mm. CORD IS MEASURED FROM THE PCB TO THE END OF THE CONNECTOR. CABLE IS TO BE MARKED WITH WIRE GAUGE, AND ALL APPLICABLE RATING AND SAFETY APPROVALS. OUTPUT CONNECTOR: FEMALE 3.96 mm PITCH, MOLEX 3961, 6 CIRCUIT, OR EQUIVALENT. INPUT CONNECTOR: IEC 60320/C14, 3 PIN MALE, PANEL MOUNT RECEPTACLE |
 | 0-65 Watts, 3′′ x 5′′ Open Frame, Universal Input, Single Output Family, ITE INPUT VOLTAGE: UNIVERSAL INPUT FROM 100 VAC TO 240 VAC INPUT CURRENT: 1.5 A @ 65 W MAXIMUM AT 100 VAC FULL LOAD INPUT FREQUENCY: 47 Hz - 63 Hz OUTPUT CURRENT: NO MINIMUM LOAD REQUIRED OUTPUT POWER (RATED): 65 WATTS MAX FREE AIR CONVECTION OUTPUT RIPPLE (PEAK TO PEAK): LESS THAN 1% OF OUTPUT VOLTAGE OUTPUT LOAD REGULATION: ±2% MEASURED AT THE OUTPUT CONNECTOR END OF THE PSU LINE REGULATION: ±0.5% OF NOMINAL VOLTAGE MEASURED AT O/P CONNECTOR TURN ON/TURN OFF OVERSHOOT: 5% MAXIMUM, 1 ms TYPICAL RECOVERY TIME FOR 25% TO 50% STEP LOAD TURN-ON DELAY: 3 SEC TYPICAL HOLD-UP TIME: 12 ms MINIMUM AT 65 W AT 120 VAC INPUT INRUSH CURRENT: 20 A MAXIMUM AT 120 VAC AND 40 A MAXIMUM AT 230 VAC EFFICIENCY: 80% TYPICAL AT NOMINAL INPUT AND FULL LOAD SWITCHING FREQUENCY: 100 kHz TYPICAL OVER-VOLTAGE PROTECTION: OUTPUT VOLTAGE LIMITED BY CROWBAR METHOD, HICCUP MODE OVER-CURRENT/SHORT CIRCUIT: HICCUP MODE, UNIT WILL RECOVER ONCE FAULT IS REMOVED OTHER PROTECTION: INPUT LINE FUSING SAFETY APPROVALS: EN60950, UL/CSA60950 3ED., EN60601, UL60601 A1/A2, CB, DEMKO, CE TO EN61000-3-2, EN610003-3, EN61000-4-2, EN61000-4-3, EN61000-4-4 EN61000-4-5, EN61000-4-6, EN61000-4-11, EMI TO EN55011 MEDICAL AND EN55022 ITE CLASS B, TESTED WITH RESISTIVE LOAD DIELECTRIC WITHSTAND VOLTAGE: 4242 VDC (3000 VAC) FROM PRIMARY TO SECONDARY 2121 VDC (1500 VAC) SECONDARY TO GROUND LEAKAGE CURRENT: LESS THAN 300 µA AT 240 VAC LINE SURGE: EN 61000-4-5 LEVEL 2 EMI: COMPLIES WITH EN55022 CLASS B AND FCC PART 15 CLASS B WHEN TESTED WITH RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED EMI. CE MARK: TESTED TO COMPLY WITH EN61000-3-2 EN610003-3 AND EN50082-1 INCLUDING EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11. MTBF (BELCORE METHOD I, CASE 1): 1.1 MILLION HRS, 40C, GROUND BENIGN OPERATING TEMPERATURE: -20°C TO 50°C AMBIENT TEMPERATURE STORAGE TEMPERATURE: -40°C TO 80°C HUMIDITY: OPERATING, NON-CONDENSING; 5% TO 90% RH
SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS. OPEN FRAME SWITCHING POWER SUPPLY WITH MOUNTING HOLES POSITIONED AS BELOW INPUT CONNECTOR (CON1): MOLEX 3-PIN WITH CENTER PIN REMOVED MOLEX PN: 26-60-4030 MATES W/PN: 09-50-3031, PIN 1: AC NEUTRAL, PIN 3: AC LINE, EC1: EARTH GROUND FOR CLASS I UNITS ONLY INPUT CONNECTOR (CON1 OPTION) WIRE HARNESS WITH MOLEX HEADER PN: 09-50-3031 WITH AWG 18 STRANDED WIRE, UL1007/UL1015 WITH CONFIGURABLE LENGTH UP TO 100 mm. BLACK OR BROWN FOR AC LINE; WHITE OR BLUE FOR AC NEUTRAL; GREEN WITH YELLOW STRIPE FOR EARTH GROUND |
 | 0-65 Watts, 3′′ x 5′′ Open Frame, Universal Input, Dual and Triple Output Family, ITE INPUT VOLTAGE: UNIVERSAL INPUT FROM 100 VAC TO 240 VAC INPUT CURRENT: 1.5 A @ 65 W MAXIMUM AT 100 VAC FULL LOAD INPUT FREQUENCY: 47 Hz - 63 Hz OUTPUT CURRENT: NO MINIMUM LOAD REQUIRED OUTPUT POWER (RATED): 65 WATTS MAX FREE AIR CONVECTION OUTPUT RIPPLE (PEAK TO PEAK): LESS THAN 1% OF OUTPUT VOLTAGE OUTPUT LOAD REGULATION: ±2% MEASURED AT THE OUTPUT CONNECTOR END OF THE PSU LINE REGULATION: ±0.5% OF NOMINAL VOLTAGE MEASURED AT O/P CONNECTOR TURN ON/TURN OFF OVERSHOOT: 5% MAXIMUM, 1 ms TYPICAL RECOVERY TIME FOR 25% TO 50% STEP LOAD TURN-ON DELAY: 3 SEC TYPICAL HOLD-UP TIME: 12 ms MINIMUM AT 65 W AT 120 VAC INPUT INRUSH CURRENT: 20 A MAXIMUM AT 120 VAC AND 40 A MAXIMUM AT 230 VAC EFFICIENCY: 80% TYPICAL AT NOMINAL INPUT AND FULL LOAD SWITCHING FREQUENCY: 100 kHz TYPICAL OVER-VOLTAGE PROTECTION: OUTPUT VOLTAGE LIMITED BY CROWBAR METHOD, HICCUP MODE OVER-CURRENT/SHORT CIRCUIT: HICCUP MODE, UNIT WILL RECOVER ONCE FAULT IS REMOVED OTHER PROTECTION: INPUT LINE FUSING SAFETY APPROVALS: EN60950, UL/CSA60950 3ED., EN60601, UL60601 A1/A2, CB, DEMKO, CE TO EN61000-3-2, EN610003-3, EN61000-4-2, EN61000-4-3, EN61000-4-4 EN61000-4-5, EN61000-4-6, EN61000-4-11, EMI TO EN55011 MEDICAL AND EN55022 ITE CLASS B, TESTED WITH RESISTIVE LOAD DIELECTRIC WITHSTAND VOLTAGE: 4242 VDC (3000 VAC) FROM PRIMARY TO SECONDARY 2121 VDC (1500 VAC) SECONDARY TO GROUND LEAKAGE CURRENT: LESS THAN 300 µA AT 240 VAC LINE SURGE: EN 61000-4-5 LEVEL 2 EMI: COMPLIES WITH EN55022 CLASS B AND FCC PART 15 CLASS B WHEN TESTED WITH RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED EMI. CE MARK: TESTED TO COMPLY WITH EN61000-3-2 EN610003-3 AND EN50082-1 INCLUDING EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11. MTBF (BELCORE METHOD I, CASE 1): 1.1 MILLION HRS, 40C, GROUND BENIGN OPERATING TEMPERATURE: -20°C TO 50°C AMBIENT TEMPERATURE STORAGE TEMPERATURE: -40°C TO 80°C HUMIDITY: OPERATING, NON-CONDENSING; 5% TO 90% RH
SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS. INPUT CONNECTOR (CON1): MOLEX 3-PIN WITH CENTER PIN REMOVED MOLEX PN: 26-60-4030 MATES WITH PN: 09-50-3031, PIN 1: AC NEUTRAL, PIN 3: AC LINE, EC1: EARTH GROUND FOR CLASS I UNITS ONLY INPUT CONNECTOR (CON1 OPTION) WIRE HARNESS WITH MOLEX HEADER PN: 09-50-3031 WITH AWG 18 STRANDED WIRE, UL1007/UL1015 WITH CONFIGURABLE LENGTH UP TO 100mm. BLACK OR BROWN FOR AC LINE; WHITE OR BLUE FOR AC NEUTRAL; GREEN WITH YELLOW STRIPE FOR EARTH GROUND |
 | 72 Watts, Switchmode Power Supply, Single Output, Family Desktop, Universal Input, ITE Class I INPUT VOLTAGE: 90 VAC TO 264 VAC INPUT CURRENT: ≤ 1.6 A RMS AT 90 VAC INPUT INPUT FREQUENCY: 47 Hz - 63 Hz OUTPUT CURRENT: NO LOAD TO FULL LOAD, NO MINIMUM LOAD REQUIRED OUTPUT POWER (RATED): 72 WATTS MAX OUTPUT RIPPLE (PEAK TO PEAK): ≤ 1% OR 100 mV OUTPUT REGULATION (LINE/LOAD): ±5% FOR MAIN OUTPUT, MEASURED AT O/P CONNECTOR LINE REGULATION: +0.5% MAX AT FULL LOAD TURN ON/TURN OFF OVERSHOOT: 4% MAX; 500 µs MAX RECOVERY TIME FOR 25% STEP LOAD TURN-ON DELAY: 1 SEC MAX HOLD-UP TIME: 16 mSEC MIN AT NOMINAL INPUT AND FULL LOAD INRUSH CURRENT: 20 A MAX AT COLD START FOR N.A. (40 A FOR EURO) EFFICIENCY: 75% TYPICAL SWITCHING FREQUENCY: 100 kHz TYPICAL OVER-VOLTAGE PROTECTION: VOLTAGE LIMITED LESS 130% OF NOMINAL VOLTAGE OVER-CURRENT/SHORT CIRCUIT: HICCUP WITH AUTO RECOVERY TO 1.1 - 1.3 IO OTHER PROTECTION: INPUT FUSING SAFETY APPROVALS: UL60950 (3rd ED.), CUL TO 22.2# 60950 (3rd ED.), TUV TO EN60950-1:2001, PSE TO J60950 CE CLASS I DIELECTRIC WITHSTAND VOLTAGE: 1500 VAC PRIMARY-SECONDARY; 1500 VAC PRIMARY-GROUND LEAKAGE CURRENT: ≤ 3.5 mA LINE SURGE: EN 61000-4-5 LEVEL 4 EMI: COMPLIES WITH EN55022, CLASS B AND FCC PART 15 CLASS B WHEN TESTED WITH A RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED CE MARK: TESTED TO COMPLY WITH EN61000-3-2 EN61000-3-3, AND EN50082-1, INCLUDING EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, LEVEL 4. UNIT IS ELIGIBLE FOR CE MARK. MTBF: GREATER THAN 200,000 HOURS AT 25°C AMBIENT TEMPERATURE OPERATING TEMPERATURE: 0°C TO 40°C STORAGE TEMPERATURE: -40°C TO 80°C HUMIDITY: 0% TO 90% RELATIVE HUMIDITY
SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS. HOUSING: HIGH IMPACT PLASTIC, 94V0 POLYCARBONATE, NON-VENTED, COLOR BLACK INPUT CONNECTOR CONFIGURATION: CLASS 1 MODEL IEC60320/C14, AC POWER RECEPTACLE WITH 3 MALE PINS. GROUND PIN CONNECTED INTERNALLY TO DC COMMON |
|