Power Supplies: Custom related categories
 | 0-5 Watts, Wall Plug-In, N.A., European, U.K., Australian Input, Single Output Family, ITE Power Adapter, Class II INPUT VOLTAGE: U = 90-264 VAC; N = 90-130 VAC; E = 180-264 VAC INPUT CURRENT: < 0.2 A RMS AT 90 VAC INPUT INPUT FREQUENCY: 47 - 63 Hz OUTPUT CURRENT: NO MINIMUM LOAD REQUIRED OUTPUT POWER (RATED): 5 WATTS MAX SWITCHING FREQUENCY OUTPUT RIPPLE (PEAK TO PEAK): 3 V-5 V MODELS 2% TYPICAL 6 V-13 V MODELS 1% TYPICAL OUTPUT REGULATION (LINE/LOAD): ± 5 % FOR MAIN OUTPUT, MEASURED AT O/P CONNECTOR LINE REGULATION: ± 2.0 % MAX AT FULL LOAD TURN ON/ TURN OFF OVERSHOOT: 4% MAX 500 µs MAX RECOVERY TIME FOR 25% STEP LOAD TURN-ON DELAY: 2000 msec MAX HOLD-UP TIME: 5 msec MIN AT NOMINAL INPUT AND FULL LOAD INRUSH CURRENT: 20 A MAX AT COLD START N.A. SWITCHING FREQUENCY: 100 kHz TYPICAL OVER-VOLTAGE PROTECTION: VOLTAGE LIMITED LESS 130% OF NOMINAL VOLTAGE OVER-CURRENT/SHORT CIRCUIT: HICCUP WITH AUTO RECOVERY TO 1.1 - 1.3 IO OTHER PROTECTION: INPUT FUSING SAFETY APPROVALS: UL60950, CUL TO 22.2# 950, TUV TO EN60950, PSE TO J60950 CE CLASS I & II DIELECTRIC WITHSTAND VOLTAGE: 4242 VDC (3000 VAC) PRIMARY-SECONDARY LEAKAGE CURRENT: ≤ 0.25 mA LINE SURGE: EN 61000-4-5 LEVEL 4 EMI: COMPLIES WITH EN55022 CLASS B AND FCC PART 15 CLASS B WHEN TESTED WITH A RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED. CE MARK: TESTED TO COMPLY WITH EN61000-3-2 EN61000-3-3AND EN50082-1, INCLUDING EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, LEVEL 4. UNIT IS ELIGIBLE FOR CE MARK. MTBF: GREATER THAN 200,000 HOURS AT 25°C AMBIENT TEMPERATURE. OPERATING TEMPERATURE: 0°C TO 40°C STORAGE TEMPERATURE: -40°C TO 80°C HUMIDITY: 0% TO 90% RELATIVE HUMIDITY
SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS. HOUSING: HIGH IMPACT PLASTIC, 94V0 POLYCARBONATE, NON-VENTED, COLOR BLACK, CUSTOMER SPECIFIED COLOR AVAILABLE UPON REQUEST |
 | 6 Watts, Wall Plug-In, Switchmode Power Supply, N.A., European, U.K., SAA Universal Input, ITE, Class II INPUT VOLTAGE: 100-240 VAC INPUT CURRENT: < 0.6 A RMS MAX INPUT FREQUENCY: 47 - 63 Hz OUTPUT CURRENT: NO LOAD TO FULL LOAD, NO MINIMUM LOAD REQUIRED OUTPUT POWER (RATED): 6 WATTS MAX OUTPUT RIPPLE (PEAK TO PEAK): 100 mV OR 1% OF OUTPUT VOLTAGE, WHICHEVER IS HIGHER OUTPUT REGULATION (LINE/LOAD): 5 % FOR MAIN OUTPUT, MEASURED AT O/P CONNECTOR LINE REGULATION: +1% MAX AT FULL LOAD TURN ON/TURN OFF OVERSHOOT: 5% MAX 500 µs MAX RECOVERY TIME FOR 25% STEP LOAD TURN-ON DELAY: 3000 msec MAX HOLD-UP TIME: 5 msec MIN AT NOMINAL INPUT AND FULL LOAD INRUSH CURRENT: 30 A MAX AT COLD START 120 VAC, 60 A MAX COLD START 230 VAC SWITCHING FREQUENCY: 66.5 kHz TYPICAL OVER-VOLTAGE PROTECTION: VOLTAGE LIMITED LESS 150% OF NOMINAL VOLTAGE OVER-CURRENT/SHORT CIRCUIT: HICCUP WITH AUTO RECOVERY TO 1.1 - 1.3 IO OTHER PROTECTION: INPUT FUSING SAFETY APPROVALS (PENDING): UL60950-1, CUL TO 22.2# 60950-1, INNOVA GS TO EN60950- CCC TO GB4943-2001, GB9254-1998, GB17625.1-2003, CE CLASS II, PSE TO J60950, CB REPORT DIELECTRIC WITHSTAND VOLTAGE: 4242 VDC PRIMARY-SECONDARY LEAKAGE CURRENT: < 3.5 mA @ 240 VAC EMI: COMPLIES WITH EN55022 CLASS B AND FCC PART 15 CLASS B WHEN TESTED WITH A RESISTIVE LOAD, BOTH CONDUCTED AND RADIATED EMI. CE MARK: TESTED TO COMPLY WITH EN61000-3-2 EN61000-3-3AND EN50082-1, INCLUDING EN61000-4-2, EN61000-4-3, EN61000- 4, EN61000-4-5, EN61000-4-6, EN61000-4-11. EFFICIENCY: COMPLIES WITH ENERGY STAR (NORTH AMERICA), CECP (CHINA), MEPS (AUSTRALIA), CODE OF CONDUCT (EUROPE) MTBF: GREATER THAN 200,000 HOURS AT 25°C AMBIENT TEMPERATURE OPERATING TEMPERATURE: 0°C TO 40°C STORAGE TEMPERATURE: -40°C TO 80°C HUMIDITY: 0% TO 90% RELATIVE HUMIDITY
SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS. UPPER & LOWER HOUSING: HIGH IMPACT PLASTIC, 94V0 POLYCARBONATE, NON-VENTED, COLOR BLACK |
 | 10 Watts, On-Board Universal Input AC-DC Encapsulated Modular Power Supplies Single & Dual Output INPUT VOLTAGE: 90-264 VAC TYPICAL. (OR 110-340 VDC) INPUT CURRENT: 0.3 A at 115 VAC./0.13 A at 230 VAC INPUT FREQUENCY: 47-63 Hz. (50/60 Hz NOM.) OR DC OUTPUT CURRENT: 10 WATTS TYPICAL OUTPUT RIPPLE (PEAK TO PEAK): 1.0% TYPICAL PEAK TO PEAK OUTPUT REGULATION (LINE/LOAD): VARIOUS WITH OUTPUT VOLTAGE. SINGLE O/P ±1.0% TYPICAL. DUAL O/P ±2.0% TYPICAL LINE REGULATION: VARIOUS WITH OUTPUT VOLTAGE SINGLE O/P: ±0.1% TYPICAL. DUAL O/P: ±0.2% TYPICAL OVP: BUILT-IN ON MAIN OUTPUT. ADJUSTABILITY: FROM -10% OF MAIN OUTPUT TILL OVP. HOLD-UP TIME: 20 ms at 115 VAC, 80 ms at 230 VAC INRUSH CURRENT: 32.5 A PEAK at 230 VAC INPUT FUSE: USE EXTERNAL FUSE. 1.0 A/250 VAC FOR PRIMARY FUSE IS SUGGESTED EFFICIENCY: 67-79% TYPICAL (VARIOUS WITH OUTPUT VOLTAGE) SWITCHING FREQUENCY: 75 kHz CIRCUIT TOPOLOGY: FIXED FREQUENCY FLYBACK CIRCUIT. TRANSIENT RESPONSE: TYPICAL PEAK DEVIATION 250 mV, RECOVERY TIME: < 3MS FOR A 25% LOAD CHANGE. CASE: IMPACT RESISTANT THERMO-PLASTIC ENCLOSURE. WEIGHT: 120 g (4.23 Oz) POWER DENSITY: 2.51 WATTS./CUBIC INCH. OVER-VOLTAGE PROTECTION: FULLY PROTECTED AGAINST OUTPUT OVERLOAD AND SHORT CIRCUIT. OLP IS SET AT ABOUT 125-150% RATING OUTPUT WATTAGE. CONSULT THE FACTORY FOR ALTERNATIVE OLP SETTINGS SAFETY APPROVALS (PENDING): UL/CUL 60950 3-RD EDITION, TUV TO EN 60950, CE DIELECTRIC WITHSTAND VOLTAGE: 3,000 VAC-OUTPUT/INPUT, 1500 VAC-INPUT/GND, 500 VAC-OUTPUT/GN EARTH LEAKAGE: LESS THAN 3.5 mA at 230 VAC EMI: MEET CISPR PUB.22/FCC CLASS B MTBF: 200,000 HOURS. MIL STD 217, 25°C OPERATING TEMPERATURE: -10 TO +70°C RANGE -10°C TO +50°C FULL LOAD WITHOUT DERATING FROM +50°C, DERATING LINEARLY TO HALF LOAD at +70°C. STORAGE TEMPERATURE: -20°C TO +85°C TEMPERATURE COEFFICIENT: ± 0.02% °C HUMIDITY: 95% RH, NON-CONDENSING COOLING: CONVECTION COOLING FOR +50°C at FULL LOAD. AT LEAST 100 LFM MOVING AIR IS RECOMMENDED FOR FULL LOAD > +50°C IN A CONFINED AREA COMMERCIAL GRADE ONLY
SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS. HOUSING : HIGH IMPACT, 94-V0 POLYCARBONATE, NON-VENTED, COLOR BLACK |
|