GlobTek, Inc.


http://www.globtek.com  
Phone: 201-784-1000
Fax: 201-784-0111
Address:
186 Veterans Dr.
Northvale, NJ 07647
map
Tell your suppliers you found them on ThomasNet

Power Supplies: Unregulated related categories

Switcher, 200 Watt, Family, Single Output, Open Frame Universal Input, ITE, Class I
INPUT RANGE:
90-264 VAC
INPUT LINE FREQUENCY:
47-63 Hz
INPUT CURRENT:
< 3.2 A RMS @ 90 VAC
INRUSH CURRENT:
40 A TYPICAL, COLD START @ 25°C
EFFICIENCY:
80% TYPICAL AT FULL LOAD
POWER FACTOR:
0.99 TYPICAL
TURN-ON DELAY:
2 SECOND TYPICAL @ 115 VAC NOMINAL LINE
INPUT LINE PROTECTION:
MOV TRANSIENT PROTECTED. INPUT LINE FUSE PROVIDED ON-BOARD
SOFT START:
STANDARD ON ALL MODELS
MAXIMUM POWER:
200 WATTS WITH FREE AIR CONVECTION COOLING
ADJUSTMENT RANGE:
±10%
LOAD REGULATION:
±2% MEASURED AT THE CONNECTOR SIDE
LINE REGULATION:
±0.5% MEASURED AT THE CONNECTOR SIDE
HIGH FREQUENCY RIPPLE:
1% OF OUTPUT VOLTAGE, PEAK TO PEAK
TURN ON/OFF OVERSHOOT:
5% MAXIMUM, 1 ms RECOVERY TIME
HOLD-UP TIME:
20 ms @ 200 W LOAD, 115 VAC NOMINAL LINE
TRANSIENT RESPONSE:
1 ms RECOVERY TO WITHIN 1% OF THE REGULATION BAND WITH NO MORE THAN 5% OUTPUT VOLTAGE DEVIATION @ 50% LOAD STEP.
OVERLOAD PROTECTION:
PROTECTED @ 115-130% OF FULL LOAD RATING FOLD BACK
SHORT CIRCUIT:
FOLDBACK, AUTORECOVER UPON REMOVAL OF SHORT
OVERVOLTAGE:
10% TO 20% ABOVE NOMINAL OUTPUT, LATCH
INDICATOR:
GREEN LED FOR OUTPUT PRESENCE
FAN OUTPUT:
12 V @ 0.15 A (UNREGULATED)
REMOTE ON/OFF:
OPEN, INHIBITS OUTPUT.
DC POWER GOOD:
TTL LOGIC GOES HIGH AFTER THE OUTPUT IS IN REGULATION. IT GOES LOW WHEN THERE IS LOSS OF REGULATION.
REMOTE SENSE:
COMPENSATE FOR 0.5 V LEAD DROP. WILL OPERATE WITHOUT REMOTE SENSE CONNECTION.
TEMPERATURE COEFFICIENT:
±0.02% PER °C, TYPICAL
OPERATING TEMPERATURE:
0°C TO 50°C FOR MODELS WITH OUTPUT < 12 V
0° TO 60°C FOR MODELS WITH OUTPUT ≥ 12 V
STORAGE TEMPERATURE:
-40°C TO 85°C
RELATIVE HUMIDITY:
OPERATING; 0-90% NON-CONDENSING
ALTITUDE:
UP TO 10000 FEET
RANDOM VIBRATION/TRANSIENT DROP:
MIL-STD 810E
MTBF:
> 200,000 HOURS @ 25° AMBIENT TEMPERATURE, FULL LOAD, NOMINAL LINE, MIL-217 STD.
SAFETY:
HIPOT (PRI-SEC) 4242 VDC FOR ITE VERSION; 5656 VDC FOR MEDICAL VERSION
EARTH LEAKAGE:
< 0.3 mA @ 50/60 Hz, 264 VAC INPUT
APPROVAL:
UL60950-1 (3RD EDITION), CUL TO 22.2 NO. 60950-1, CB REPORT, DEMKO TO EN60950-1
EMI:
EN55022 CLASS B AND FCC PART 15, TESTED WITH RESISTIVE LOAD.
CE MARK:
EN61000-3-2, EN61000-3-3 AND EN50082-1, INCLUDING EN61000-4-2 (SYSTEM LEVEL), EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 LEVEL 4
MODEL DESCRIPTION:
GT-9200P1323.3-X.X TO 20048-X.X GT: GLOBTEK SERIES “-“ (DASH) FOR ITE GRADE 9200: FAMILY DESIGNATOR 1323.3 TO 20048: 132W 3.3V TO 200W 48V OUTPUT POWER OUTPUT VOLTAGE X.X: OUTPUT VOLTAGE DEVIATION FROM STANDARD MODEL BY SUBTRACTING X.X VOLT FROM STANDARD OUTPUT VOLTAGE. S: INPUT HEADER AND OUTPUT METAL TERMINAL ON BOARD. R: IEC INPUT RECEPTACLE AND OUTPUT METAL TERMINAL ON BOARD. HIOXXX: INPUT AND OUTPUT WIRE HARNESS. WHERE XXX CAN BE FROM 000 TO 999 (MAXIMUM LENGTH FOR INPUT IS 100 MM AND 200 MM FOR OUTPUT). HORXXX: IEC INPUT RECEPTACLE ON BOARD AND OUTPUT WIRE HARNESS. WHERE XXX CAN BE FROM 000 TO 999 (MAXIMUM WIRE LENGTH FOR OUTPUT IS 200 MM). HOXXX: INPUT HEADER ON BOARD AND OUTPUT WIRE HARNESS. WHERE XXX CAN BE FROM 000 TO 999 (MAXIMUM WIRE LENGTH FOR OUTPUT IS 200 MM). HIXXX: INPUT WIRE HARNESS. OUTPUT METAL TERMINAL ON BOARD. WHERE XXX CAN BE FROM 000 TO 999 (MAXIMUM WIRE LENGTH FOR INPUT IS 100 MM).

SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS.
Switcher, 200 Watt, Family, Single Output, Open Frame Universal Input, Medical, Class I
INPUT RANGE:
90-264 VAC
INPUT LINE FREQUENCY:
47-63 Hz
INPUT CURRENT:
< 3.2 A RMS @ 90 VAC
INRUSH CURRENT:
40 A TYPICAL, COLD START @ 25°C
EFFICIENCY:
80% TYPICAL AT FULL LOAD
POWER FACTOR:
0.99 TYPICAL
TURN-ON DELAY:
2 SECOND TYPICAL @ 115 VAC NOMINAL LINE
INPUT LINE PROTECTION:
MOV TRANSIENT PROTECTED. INPUT LINE FUSE PROVIDED ON-BOARD
SOFT START:
STANDARD ON ALL MODELS
MAXIMUM POWER:
200 WATTS WITH FREE AIR CONVECTION COOLING
ADJUSTMENT RANGE:
±10%
LOAD REGULATION:
±2% MEASURED AT THE CONNECTOR SIDE
LINE REGULATION:
±0.5% MEASURED AT THE CONNECTOR SIDE
HIGH FREQUENCY RIPPLE:
1% OF OUTPUT VOLTAGE, PEAK TO PEAK
TURN ON/OFF OVERSHOOT:
5% MAXIMUM, 1ms RECOVERY TIME
HOLD-UP TIME:
20 ms @ 200 W LOAD, 115 VAC NOMINAL LINE
TRANSIENT RESPONSE:
1 ms RECOVERY TO WITHIN 1% OF THE REGULATION BAND WITH NO MORE THAN 5% OUTPUT VOLTAGE DEVIATION @ 50% LOAD STEP.
OVERLOAD PROTECTION:
PROTECTED @ 115-130% OF FULL LOAD RATING FOLD BACK
SHORT CIRCUIT:
FOLDBACK, AUTORECOVER UPON REMOVAL OF SHORT
OVERVOLTAGE:
10% TO 20% ABOVE NOMINAL OUTPUT, LATCH
INDICATOR:
GREEN LED FOR OUTPUT PRESENCE
FAN OUTPUT:
12 V @ 0.15 A (UNREGULATED)
REMOTE ON/OFF:
OPEN, INHIBITS OUTPUT.
DC POWER GOOD:
TTL LOGIC GOES HIGH AFTER THE OUTPUT IS IN REGULATION. IT GOES LOW WHEN THERE IS LOSS OF REGULATION.
REMOTE SENSE:
COMPENSATE FOR 0.5 V LEAD DROP. WILL OPERATE WITHOUT REMOTE SENSE CONNECTION.
TEMPERATURE COEFFICIENT:
±0.02% PER °C, TYPICAL
OPERATING TEMPERATURE:
0° TO 50°C FOR MODELS WITH OUTPUT < 12 V; 0° TO 60°C FOR MODELS WITH OUTPUT ≥ 12 V
STORAGE TEMPERATURE:
-40° TO 85°C
RELATIVE HUMIDITY:
OPERATING; 0-90% NON-CONDENSING
ALTITUDE:
UP TO 10000 FEET
RANDOM VIBRATION/TRANSIENT DROP:
MIL-STD 810E
MTBF:
> 200,000 HOURS @ 25°C AMBIENT TEMPERATURE, FULL LOAD, NOMINAL LINE, MIL-217 STD.
SAFETY:
HIPOT (PRI-SEC) 4242 VDC FOR ITE VERSION 5656 VDC FOR MEDICAL VERSION
EARTH LEAKAGE:
< 0.3 mA @ 50/60 Hz, 264 VAC INPUT
APPROVAL:
UL60601-1, CUL TO 22.2 NO.60601-1, CB REPORT, DEMKO TO EN60601-1.
EMI:
EN55022 CLASS B AND FCC PART 15, TESTED WITH RESISTIVE LOAD.
CE MARK:
EN61000-3-2, EN61000-3-3 AND EN50082-1, INCLUDING EN61000-4-2 (SYSTEM LEVEL), EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 LEVEL 4
MODEL DESCRIPTION
GTM9200P1323.3-X.X TO 20048-X.X GT: GLOBTEK SERIES M: MEDICAL GRADE 9200: FAMILY DESIGNATOR 1323.3 TO 20048: 132 W 3.3 V TO 200 W 48 V OUTPUT POWER OUTPUT VOLTAGE X.X: OUTPUT VOLTAGE DEVIATION FROM STANDARD MODEL BY SUBTRACTING X.X VOLT FROM STANDARD OUTPUT VOLTAGE. S: INPUT HEADER AND OUTPUT METAL TERMINAL ON BOARD. R: IEC INPUT RECEPTACLE AND OUTPUT METAL TERMINAL ON BOARD. HIOXXX: INPUT AND OUTPUT WIRE HARNESS. WHERE XXX CAN BE FROM 000 TO 999 (MAXIMUM LENGTH FOR INPUT IS 100 MM AND 200 MM FOR OUTPUT). HORXXX: IEC INPUT RECEPTACLE ON BOARD AND OUTPUT WIRE HARNESS. WHERE XXX CAN BE FROM 000 TO 999 (MAXIMUM WIRE LENGTH FOR OUTPUT IS 200 MM). HOXXX: INPUT HEADER ON BOARD AND OUTPUT WIRE HARNESS. WHERE XXX CAN BE FROM 000 TO 999 (MAXIMUM WIRE LENGTH FOR OUTPUT IS 200 MM). HIXXX: INPUT WIRE HARNESS. OUTPUT METAL TERMINAL ON BOARD. WHERE XXX CAN BE FROM 000 TO 999 (MAXIMUM WIRE LENGTH FOR INPUT IS 100 MM).

SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS.
Back to top
Home | Browse Categories | Featured Companies Sitemap | Featured Categories Sitemap
Guides | Forums | FAQs | Contact ThomasNet | Provide Feedback

Log In to MyThomas | Sign Up for MyThomas | Log In to Client Center

Advertising Services | Free Listing | Press Room | Careers

© 2009 Thomas Publishing Company. All rights reserved. See Terms and Conditions or Privacy Statement. Last Modified December 25, 2009.
Sign Up | Log In | Product News | Promote Your Business