Calibrators: Portable related categories
 | Handy Calibrator CA11E Voltage Calibrator - Current Calibrator
Signal source: DCV (Max. 30V), DCA (Max. 24 mA) Measurement: DCV (Max. 30V), DCA (Max. 100 mA) Features: Auto step (4 to 20mA), 20mA SINK, Sweep function Options: CA11E-2 Includes rubber boot, strap and accessory case |
 | Handy Multifunction Calibrator CA71 Handy Multifunction Calibrator Signal source: DCV, DCA, Resistance, RTD, TC (10 kinds), Frequency, Pulse Measurement: DCV, DCA, ACV, Resistance, RTD, TC (10 kinds), Frequency, Pulse Features: Simultaneous signal source and measurement capacity, a wide array of useful functions, Easy operation, Online communication function Options: CA71/SP1 includes Communications cable, data logging softare, 120V power supply, magnetic backing instrument case, source/measure cables, NIST traceable certification. |
 | Handy Calibrator CA150
Signal source: DCV, DCA, OHM, RTD, TC (10 kinds), Frequency, Pulse
Measurement: DCV, DCA, OHM, RTD, TC (10 kinds), Frequency, Pulse
Features: Highly accurate within 0.02% of the DC voltage range for source and measure. Source and measurement can be performed simultaneously. Vertical type with large-screen display.Loop power supply function (24 VDC at a load of up to 22 mA) It is possible to measure current in the mA range while supplying power.Sink function. Sweep functions that allow 3 types of continuous outputs.
Options: CA150/SP1 includes: 94010 Idapter, 94015: NiMH Battery, 93027: Main Body case with strap |
 | Model YPC4000 Portable Modular Calibrator with HART® Communications YPC4000 is a combination Calibrator / HART Communicator that reduces the time spent on field calibrations and the number of test instruments that have to
be carried into the field. The YPC4000 Series delivers the versatility of a modular calibrator and the convenience of HART communications in one handheld unit. Users can view up to four measurements simultaneously on the high resolution LCD or compare HART PV and AO values to corresponding values measured. Available sensor modules include a variety of differential, gauge, vacuum and absolute pressure as well as voltage, current and temperature. A voltage and current meter is integral to the base unit. All HART field devices can be configured, polled, and trimmed using HARTcommunications. Device Specific commands for more than 200 supported devices, including EJA/EJX pressure transmitters, YTA Temperature Transmitters, and Yewflo are available. |
 | Handy Temperature Calibrator CA12E
Temperature Calibrator
Signal source: TC (10 kinds), RTD, DC100 mV, 4000 Measurement: TC (10 kinds), RTD, DC100 mV, 4000 Features: Selectable RTD (Pt100 or JPt100), Built-in RJC Options: CA12E-2 Includes rubber boot, strap and accessory case |
|